Posted inNetApp Certified Implementation Engineer SAN Specialist / NetApp Data Track Certification Collection / NS0-520 / NS0-520 dumps / NS0-520 dumps pdf / NS0-520 dumps VCE / NS0-520 exam dumps / ONTAP (NS0-520)

[Update Nov 2022] Use Lead4Pass NS0-520 dumps to take the exam with a guaranteed pass

NetApp Certified Implementation Engineer - SAN ONTAP (NS0-520) exam

Lead4Pass NS0-520 dumps with PDF file and VCE practice exam engine contains 60 up-to-date exam questions and answers covering NetApp Certified Implementation Engineer – SAN ONTAP (NS0-520) exam topics.

Candidates only need to download NS0-520 dumps PDF or NS0-520 dumps VCE: https://www.leads4pass.com/ns0-520.html (NS0-520 dumps), and practice hard to ensure 100% pass the exam.

NetApp Certified Implementation Engineer – SAN ONTAP (NS0-520) exam includes ONTAP® SAN solution assessment, ONTAP SAN planning, ONTAP SAN implementation and configuration, and ONTAP SAN implementation testing and troubleshooting.

Share part of Netapp NS0-520 dumps PDF online download for free:

https://drive.google.com/file/d/1h8Ejt9TTzjdbKoNVqD4_dWxZKuLSmanQ/

The following is a comprehensive sharing of some of the latest Netapp NS0-520 dumps exam questions and answers:

Number of exam questionsExam nameFromRelease timeLast updated
15NetApp Certified Implementation Engineer – SAN ONTAPLead4PassNov 14, 2022NS0-520 dumps
New Question 1:

A customer wants to deploy NVMe/FC along with an existing FC SAN fabric using ONTAP 9.8. In this scenario, which two actions are correct? (Choose two.)

A. Enable NVMe/FC on the existing FC SVM.

B. Create new zoning on fabric switches.

C. Upgrade your FC switches from 16 GB to 32 GB.

D. Use existing zoning on fabric switches.

 

Correct Answer: CD


New Question 2:

 

Click the Exhibit button.

new ns0-520 dumps questions 2

You are configuring a new NetApp ONTAP cluster and are connecting the nodes to Cisco MDS SAN switches. You connect one of the nodes to switch port fc1/11 and run the commands that are shown in the exhibit. The SAN LIFs are enabled but are not operationally online, and none of the SAN hosts can access their LUNs on the ONTAP cluster.

In this scenario, which configuration would cause this problem?

A. NPIV is not enabled on the switches.

B. Interoperability mode is not enabled on the switches.

C. NPV is not enabled on the switches.

D. The in-order guarantee is not enabled on the switch.

 

Correct Answer: B


New Question 3:

 

You are installing an AFF A250 system with ONTAP 9.8 software. Your customer asks you about the recommended LIF configuration for the iSCSI protocol.

In this scenario, which two statements are correct? (Choose two.)

A. Each node in an iSCSI configuration must be connected to a minimum of two Ethernet switches.

B. Each SVM in an iSCSI configuration must have a minimum of two LIFs per node.

C. All LIFs from the SVM are connected to a single Ethernet switch.

D. Each SVM in an iSCSI configuration must have a minimum of one LIF per node.

 

Correct Answer: AC


New Question 4:

 

A customer has a 4-node cluster consisting of a FAS8020 system and an AFF A220 system that is running iSCSI workloads across two separate SVMs. The FAS8020 system is reaching end of support, so they add a new AFF A400 system to migrate workloads off the FAS8020 system. The customer wants to migrate data off the FAS8020 aggregate n1_aggr1 on SVM2 to the AFF A400 aggregate n5_aggr1 on SVM1.

In this scenario, which NetApp command would accomplish this task?

A. volume move

B. aggregate reallocation

C. volume reallocation

D. volume rehost

 

Correct Answer: D


New Question 5:

 

Which NetApp tool provides a detailed inventory of SAN components?

A. Hardware Universe

B. Active IQ Config Advisor

C. Interoperability Matrix Tool

D. Active IQ OneCollect

 

Correct Answer: C


New Question 6:

 

You want to move a SAN LIF and preserve its configuration information and avoid rezoning the switch fabric.

In this scenario, which two steps must be performed to fulfill this goal? (Choose two.)

A. Keep the SAN LIF online before it is moved.

B. Take the SAN LIF offline before it is moved.

C. Move the SAN LIFs to another node in a cluster on different storage virtual machines (SVMs).

D. Move the SAN LIFs to another node in a cluster on existing storage virtual machines (SVMs).

 

Correct Answer: BD


New Question 7:

 

Click the Exhibit button.

new ns0-520 dumps questions 7

In an NVMe/FC environment, the host cannot discover the namespace on the AFF system. Referring to the exhibit, what is the problem?

A. The NQN is not correct.

B. The host MPIO drivers are not installed.

C. NVMe is not supported on the FC adapter.

D. The NVMe service is not running on the SVM.

 

Correct Answer: B


New Question 8:

 

You are designing a new 4-node AFF A400 SAN cluster with 20 iSCSI hosts. Each AFF A400 node will have four data LIFs. Each iSCSI host needs to access every LUN over two LIFs per node on every SAN node.

In this scenario, which NetApp SAN feature enables this connectivity?

A. selective LUN mapping

B. port sets

C. HBA queue depth

D. asymmetric namespace

 

Correct Answer: A


New Question 9:

 

You are planning on implementing a new SAN on AFF A400 controllers. The data set consists of unique 1 KB files that will be encrypted before being written to the SAN.

In this scenario, which ONTAP inline storage efficiency will provide 4:1 savings for this workload?

A. autogrow

B. deduplication

C. compression

D. compaction

 

Correct Answer: B


New Question 10:

 

While changing the network connections on your ONTAP cluster from twinax to fiber, the ports experience network connectivity issues. You want to verify which speeds the ports support and ensure that you have supported transceivers.

In this scenario, which two action would accomplish this task? (Choose two.)

A. Use Hardware Universe to determine the supported port speeds.

B. Use the Interoperability Matrix Tool to determine the supported port speeds.

C. Use Hardware Universe to determine the supported transceivers.

D. Use the Interoperability Matrix Toll to determine the supported transceivers.

 

Correct Answer: BC


New Question 11:

 

An administrator is configuring their existing Ethernet network switches to provide iSCSI LUNs to several servers. The network switches are also used for other traffic from various hosts.

In this scenario, which statement is true?

A. Use multiple VLANs to isolate iSCSI traffic from other network traffic.

B. Configure the MTU size to be larger on the switch and storage than on the host.

C. Increase the ratio of access ports to trunk ports to 2:1.

D. NetApp recommends using the same LIFs for NFS and iSCSI traffic.

 

Correct Answer: D


New Question 12:

 

You are configuring FC ports on front-end SAN switches for a 4-node MetroCluster configuration across two data centers. You need to ensure that each data center serves FC LUNs when a FC port goes offline in one data center.

In this scenario, which front-end switch setting must be modified to avoid overlap when a new port comes online?

A. NPIV enabled

B. ANA mapped

C. WWPN reject

D. WWNN reject

 

Correct Answer: C


New Question 13:

 

You are testing FPC path failures on a 2-node NetApp AFF All SAN Array and verify that persistent ports are correctly enabled. Before testing, a host sees four optimized paths to a LUN. You perform a node takeover and re-check the host.

Which statement is true after the node takeover?

A. The host sees two optimized paths and two non-optimized paths to the LUN.

B. The host sees two optimized paths and two dead paths to the LUN.

C. The host sees two non-optimized paths and two dead paths to the LUN.

D. The host sees four optimized paths to the LUN.

 

Correct Answer: A


New Question 14:

 

You have implemented FabricPool on your AFF ASA ONTAP 9.8 cluster. An archived database has become very active, and it requires FabricPool adjustments.

Which two steps are required to address this issue? (Choose two.)

A. Set the space guarantee on the volume.

B. Set the tiering-policy to none.

C. Use the promote cloud-retrieval-policy.

D. Remove all Snapshot copies.

 

Correct Answer: AB


New Question 15:

 

You are asked to configure a small environment for a branch office. The customer has two new VMware ESXi hosts and a NetApp FAS2750 for the site. They want to allocate 10 GB for their iSCSI network to be used for datastores. However, they do not want to purchase any new switches for the environment.

In this scenario, which statement is correct?

A. The SMB protocol will need to be used.

B. Configure direct attached connections between the two hosts and storage.

C. The environment will have to be configured with 1 Gb networking.

D. 10 Gb switches are required for this configuration.

 

Correct Answer: B


 

NetAppexamdumps is a website for collecting Netapp certification resources. This site shares all popular exam items of Netapp Data Track, Hybrid Cloud Track, and Converged Infrastructure Track.

Part of the Netapp NS0-520 dumps exam questions and answers shared above are for candidate verification, welcome to download the latest NS0-520 dumps:https://www.leads4pass.com/ns0-520.html (60 Q&A PDF+VCE), Guaranteed first-attempt pass for the NetApp Certified Implementation Engineer – SAN ONTAP (NS0-520) exam.

BTW, download a part of Netapp NS0-520 dumps PDF to study locally: https://drive.google.com/file/d/1h8Ejt9TTzjdbKoNVqD4_dWxZKuLSmanQ/

On the Netappexamdumps platform, you can search for all free NetApp exam questions and test or practice for yourself online. And you can download PDF files. Any other questions, you can email [email protected]