Posted inCisco and NetApp FlexPod Design Specialist (NS0-173) / NetApp Converged Infrastructure Track Certification Collection / NS0-173 / NS0-173 dumps / NS0-173 dumps pdf / NS0-173 dumps VCE / NS0-173 exam dumps

[Update Jan 2022] Use Lead4Pass NS0-173 dumps to take the exam with a guaranteed pass

Cisco and NetApp FlexPod Design ns0-173 exam

Lead4Pass NS0-173 dumps with PDF file and VCE practice exam engine contains 60 up-to-date exam questions and answers covering Cisco and NetApp FlexPod Design (NS0-173) exam topics.
Candidates only need to download NS0-173 dumps PDF or NS0-173 dumps VCE: https://www.leads4pass.com/ns0-173.html (NS0-173 dumps), and practice hard to ensure 100% pass the exam.

Share part of Netapp NS0-173 dumps PDF online download for free:

https://drive.google.com/file/d/1mC2EmDVXFEd8OjGKxfd3dYRR-0sylPX_/

The following is a comprehensive sharing of some of the latest Netapp NS0-173 dumps exam questions and answers:

Number of exam questionsExam nameFromRelease time
15Cisco and NetApp FlexPod Design SpecialistLead4PassJan 06, 2022
New Question 1:

Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.

Which two solutions allow the customer to expand the current storage system? (Choose two.)

A. a two-node AFF A200 with a 3.8 TB NSE SSD

B. a DS224C with twenty-four 3.8 TB SSDs

C. a DS4246 with twenty-four 6 TB NL-SAS HDDs

D. a two-node FAS8200 with a 4 TB NL-SAS HDD

 

Correct Answer: BD


New Question 2:

 

The storage administrator must change the vHBA settings bound to a template associated with a production server.

What happens when the settings are reconfigured in this scenario?

A. The vHBA configuration change does not affect LUN access.

B. The server that is associated with the service profile reboots.

C. The service profile template that is associated with the server is initialized.

D. The vHBA template is deleted from UCS Manager.

 

Correct Answer: C


New Question 3:

 

A customer has installed FlexPod and verified that all wiring connections are correct. However, the customer cannot see any FC LUNs from the NetApp AFF systems.

In this scenario, which three configuration elements should the customer verify? (Choose three.)

A. FC zoning

B. igroup configuration

C. ALUA settings

D. FC portsets E. MTU configuration

 

Correct Answer: BDE


New Question 4:

 

You are a data center architect at a service provider. You need to configure a new multi-tenant FlexPod service offering.

Which three UCS Manager features will you need to accomplish this task? (Choose three.)

A. auto-discovery

B. role-based access control

C. service profiles

D. virtualization support

E. policies

 

Correct Answer: BCE


New Question 5:

 

A customer is designing a FlexPod solution with VMware 6.x in a SAN boot environment using FCoE. The customer has predetermined the WWPN values for the NetApp LIFs and the UCS vHBAs. The customer is now working on the design workflow for the SAN boot process.

In this scenario, which three FlexPod environment objects are required for SAN connectivity? (Choose three.)

A. NetApp export policies

B. UCS boot policies

C. UCS IQN pools

D. initiator groups

E. FC zones

 

Correct Answer: ABC


New Question 6:

 

A customer is evaluating management tools for a new FlexPod infrastructure. They desire a tool that can orchestrate the provisioning of UCS compute nodes, NetApp storage, and VMware networking.

Which tool satisfies the requirements of this customer\’s heterogeneous environment?

A. UCS Central

B. NetApp OnCommand Unified Manager

C. NetApp OnCommand Insight

D. UCS Director

 

Correct Answer: D


New Question 7:

 

An administrator decides to connect storage directly to UCS Fabric Interconnect to support FCoE within a FlexPod configuration.

In this scenario, which port type should be defined on the Fabric Interconnect ports that are connected to the storage controller?

A. monitor port

B. appliance port

C. uplink port

D. server port

 

Correct Answer: C


New Question 8:

 

A customer has deployed a FlexPod Datacenter with the Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.

Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)

A. Cisco

B. VMware

C. Microsoft

D. NetApp

E. Red Hat

 

Correct Answer: ADE

Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_openstack_osp6_design.html


New Question 9:

 

Your customer has a FlexPod implementation and wants to use life-cycle management to validate, monitor, and optimize the FlexPod infrastructure.

In this situation, which management tool should your customer use?

A. NetApp OnCommand Unified Manager

B. NetApp Converged System Advisor

C. Cisco UCS Manager

D. Cisco UCS Director

 

Correct Answer: D

Cisco UCS Director can be an integral companion for FlexPod because it allows holistic management through centralized automation and orchestration from a single, unified view.

When FlexPod and Cisco UCS Director are combined, IT can shift time and focus from managing infrastructure to delivering new service innovation.

Used together, FlexPod and Cisco UCS Director deliver: Reference: https://www.netapp.com/media/16859-tr-3884.pdf


New Question 10:

 

A customer has a FlexPod Express configuration with a FAS2720 system. The company has opened a new remote location and will purchase a FlexPod Express configuration with a FAS2750 system. The business requires that the data be replicated in the new location.

Which two software applications accomplish this task? (Choose two.)

A. SnapVault

B. SnapRestore

C. SnapMirror

D. FlexCache

 

Correct Answer: CD

FlexClone: Instant virtual copies with file and volume granularity SnapMirror: Integrated data replication technology for simple, efficient, flexible disaster recovery and backup use cases

Reference: https://www.inneo.ch/files/content/Informationstechnologien/Storage-Server-Netzwerk/datenblatt-netapp-fas-2700-storage.pdf


New Question 11:

 

A customer wants to design a FlexPod configuration based on a CVD that was published 10 months ago. The customer wants to ensure that they are using the latest hardware and software versions.

In this scenario, which two tools are used to identify the latest supported hardware and software? (Choose two.)

A. NetApp Interoperability Matrix Tool

B. NetApp OnCommand System Manager

C. Cisco UCS Hardware and Software Interoperability Matrix

D. Cisco UCS Director

 

Correct Answer: CD

C: When using this matrix to determine recommended driver versions for your server configuration, please reference the server\’s Blade/Rack Bundle firmware version for the recommended driver in the event that your servers are running Mixed Firmware from your Infrastructure Bundle.

D: Cisco UCS Director delivers unified, highly secure management for supported compute, network, storage, and virtualization platforms and for the industry\’s leading converged infrastructure solutions

Reference: https://ucshcltool.cloudapps.cisco.com/public/# https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-director/release-notes/6-7/cisco-ucsdirector-release-notes-67.html


New Question 12:

 

You are designing a FlexPod solution that requires 32 ports running at 40 Gbps.

To satisfy this requirement, which Cisco Fabric Interconnect should you deploy?

A. 6332-16UP

B. 6332

C. 6248UP

D. 6296UP

 

Correct Answer: B

FI 6332 is a one-rack-unit (1RU) 40 Gigabit Ethernet, and FCoE switch offering up to 2.56 Tbps throughput

and up to 32 ports. The switch has 32 40Gbps fixed Ethernet.

Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi60u2_fc_design.html


New Question 13:

 

You are configuring high availability within the network layer of your FlexPod configuration.

In this scenario, what are two Cisco best practices for designing vPC on your Cisco 9000 Series switches? (Choose two.)

A. Peer keep-alive connectivity between the switches should be established.

B. A minimum of four 10GB Ethernet connections are required for vPC.

C. The vPC auto-recovery feature should be enabled.

D. Port channels should be configured for LACP passive mode.

 

Correct Answer: AB

vPC also relies on the periodic keepalive messages to determine when one of the connected devices on the peer link fails. vPC peer link?

The link is used to synchronize states between the vPC peer devices. Both ends must be on 10-Gigabit Ethernet or 40-Gigabit Ethernet interfaces.

 


New Question 14:

 

A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with the Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.

In this scenario, which three configurations are supported? (Choose three.)

A. Cluster mode

B. Direct Connect mode

C. SingleConnect mode

D. DualWire Management mode

E. Multipath mode

 

Correct Answer: BCD

Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic.

A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.

SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic.

This feature is referred to as SingleConnect. Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack-Mount Server directly to the FIs.

This option enables Cisco UCS Manager to manage the Cisco UCS C-Series Rack-Mount Servers using a single cable for both management traffic and data traffic.

The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.

Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-SeriesIntegration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html


New Question 15:

 

A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.

In this scenario, which model of Cisco UCS server IOM is required?

A. 2204XP.

B. 2208XP

C. 2232

D. 2304

 

Correct Answer: A

The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports that connect the blade chassis to the fabric interconnect.

Reference: https://www.cisco.com/c/dam/ en/us/products/collateral/servers-unified-computing/ucs-b-series-blade-servers/spec_sheet_c17644224.pdf


 

NetAppexamdumps is a website for collecting Netapp certification resources. This site shares all popular exam items of Netapp Data Track, Hybrid Cloud Track, and Converged Infrastructure Track.

Part of the Netapp NS0-173 dumps exam questions and answers shared above are for candidate verification, welcome to download the latest NS0-173 dumps:https://www.leads4pass.com/ns0-173.html (60 Q&A PDF+VCE), Guaranteed first-attempt pass for the Cisco and NetApp FlexPod Design (NS0-173) exam.

BTW, download a part of Netapp NS0-173 dumps PDF to study locally: https://drive.google.com/file/d/1mC2EmDVXFEd8OjGKxfd3dYRR-0sylPX_/

On the Netappexamdumps platform, you can search for all free NetApp exam questions and test or practice for yourself online. And you can download PDF files. Any other questions, you can email [email protected]