Posted inE-Series (NS0-515) / NetApp Certified Implementation Engineer SAN Specialist / NetApp Data Track Certification Collection / NS0-515 / NS0-515 dumps / NS0-515 dumps pdf / NS0-515 dumps VCE / NS0-515 exam dumps

[Update May 2022] Use Lead4Pass NS0-515 dumps to take the exam with a guaranteed pass

Lead4Pass NS0-515 dumps with PDF file and VCE practice exam engine contains 59 up-to-date exam questions and answers covering NetApp Certified Implementation Engineer – SAN, E-Series (NS0-515) exam topics.

Candidates only need to download NS0-515 dumps PDF or NS0-515 dumps VCE: https://www.leads4pass.com/ns0-515.html (NS0-515 dumps), and practice hard to ensure 100% pass the exam.

NetApp Certified Implementation Engineer – SAN, E-Series (NS0-515) exam includes Storage Configuration, Documentation, Hardware, Host Side, Management, Toolbox, Protection, SAN, and Troubleshooting.

Share part of Netapp NS0-515 dumps PDF online download for free:

https://drive.google.com/file/d/1eCRmfp1r4NSsBLOmHLZXbZIsjkt172iK/

The following is a comprehensive sharing of some of the latest Netapp NS0-515 dumps exam questions and answers:

Number of exam questionsExam nameFromRelease time
15NetApp Certified Implementation Engineer – SAN, E-SeriesLead4PassMay 5, 2022
New Question 1:

Click the Exhibit button.

new ns0-515 dumps questions 1

An administrator is asked to create a 5532 GiB volume from the volume group. Referring to the exhibit, how would the administrator complete this request?

A. Create the volume after performing space reclamation

B. Create the volume after consolidating the capacity

C. Create the volume from the available capacity

D. Create the volume after adjusting the preservation capacity

 

Correct Answer: C


New Question 2:

 

A customer intends to use an E2812 system without expansion shelves. The specification for their Windows host requires that six E-Series data volumes be used. In this scenario, how should the system be configured?

A. one DDP with all the volumes

B. three DDPs with the volumes divided equally

C. one DDP for each volume

D. two DDPs with the volumes divided equally

 

Correct Answer: A

Reference: https://www.netapp.com/us/media/tr-4725.pdf (37)


New Question 3:

 

A company implemented Automatic Load Balancing (ALB). When the controller workloads are monitored, it becomes obvious that there is an imbalance and that ALB is not working correctly. In this scenario, what are two causes of the problem? (Choose two.)

A. The company implemented a load balancing min-min algorithm that does not support ALB

B. The company implemented an adaptive load balancing agent that does not support ALB

C. The company implemented a host multipath driver that does not support ALB

D. The company implemented a host type that does not support ALB

 

Correct Answer: CD

Reference: https://mysupport.netapp.com/NOW/public/eseries/sam/index.html#page/GUID-8538272A-B802-49D9-9EA2-96C82DAD26A2/GUID-90A829B6-ACEE-41C6-8595-91C7D90554EB.html


New Question 4:

 

A company wants the most scalable host-side connection topology for E-Series systems. In this scenario, which FC topology would satisfy the requirement?

A. direct connect

B. fabric attach

C. private loop

D. arbitrated loop

 

Correct Answer: B


New Question 5:

 

Click the Exhibit button.

new ns0-515 dumps questions 5

A customer has a raised floor with a weight limit of 700 lb. per floor tile. The customer\’s data cabinet weights 90 lb. and covers a single floor tile. Referring to the exhibit, what is the maximum number of E2824 shelves possible to be installed?

A. 22

B. 10

C. 6

D. 14

 

Correct Answer: A


New Question 6:

 

A customer needs to add an EF280 with FC into its existing Brocade fabric but the FC ports in the SANtricity System Manager are showing the FC ports as down and the LED on the FC HIC is amber.

Which three tasks does the installer need to complete to solve this problem? (Choose three.)

A. Verify that the ports are enabled on the switch

B. Verify that the cables are plugged into the switch

C. Verify that the server HBA has the boot BIOS enabled

D. Verify that the EF280s management port is up

E. Verify that the switch zone has the WWPNs for the EF280 and Server HBAs

 

Correct Answer: ABE


New Question 7:

 

What are two base host connectivity selections that are provided by the E2800 controller? (Choose two.)

A. FC

B. SAS

C. IB

D. iSCSI

 

Correct Answer: AD

Reference: https://www.netapp.com/us/media/tr-4725.pdf


New Question 8:

 

Click the Exhibit button.

new ns0-515 dumps questions 8

Referring to the exhibit, what is the reason for the errors that are shown on port 5 on the switch of one of the fabrics?

A. protocol errors, encoding errors, or conversion errors

B. faulty SFPs, cables, or patch panels

C. twisted cables, wrong plugs, or cable material

D. wrong switch configuration

 

Correct Answer: A


New Question 9:

 

An administrator is asked to create an asynchronous mirroring environment that supports multiple mirroring relationships, each with different recovery point objectives (RPOs). In this scenario, how does the administrator create this environment?

A. The administrator creates a mirror group with the appropriate RPOs

B. The administrator creates multiple mirror pairs, each with its own schedule and RPO

C. The administrator creates a single consistency group with multiple RPOs

D. The administrator creates multiple mirror consistency groups with the appropriate RPOs

 

Correct Answer: A

Reference: https://www.netapp.com/us/media/tr-4656.pdf


New Question 10:

 

A customer has an E5760 array with a 30-drive Dynamic Disk Pool (DDP) that uses 800 GB SSD drives. The customer needs to expand the pool by one drive but has only a 1.6 TB SSD drive available. In this scenario, what happens when the customer attempts to add the 1.6 TB drive to the existing pool?

A. The pool is expanded by 1.6 TB

B. The pool is expanded by 1.6 TiB

C. The pool is expanded by 800 GB

D. An error occurs, and the add fails

 

Correct Answer: A


New Question 11:

 

Your company has an E-Series system connected to Cisco MDS switches. You are asked to provision a volume on a new Windows host, but the Windows host is unable to connect to the volume on the E-Series system. All other Windows hosts in the fabric are able to connect to their volumes.

In this scenario, which three actions should you perform to accomplish this task? (Choose three.)

A. Create a new virtual SAN (VSAN)

B. Obtain the WWPN for the Windows HBA

C. Restart the switches

D. Create a single-initiator zone with the host and E-Series system

E. Add a zone to the active zoneset

 

Correct Answer: BCE


New Question 12:

 

Which iSCSI setting would you change from its default value to increase the throughput of an iSCSI host port on a NetApp E-Series system?

A. maximum transmission unit (MTU)

B. flow control

C. Challenge-Handshake Authentication Protocol (CHAP)

D. Time to Live (TTL)

 

Correct Answer: A

Reference: https://www.netapp.com/us/media/tr-3409.pdf


New Question 13:

 

Which alerting method would be configured using the SANtricity System Manager setup wizard?

A. Syslog

B. SNMP

C. Web Services Proxy

D. Email

 

Correct Answer: B

Reference: https://docs.oracle.com/cd/E19298-01/CRCM1573/CRCM1573.pdf


New Question 14:

 

A customer has launched a data analytics initiative and has been transferring old data into the new data lake. The customer has discovered some data read errors during the transfer process. In this scenario, how should the customer have avoided these data integrity issues?

A. by ensuring that data assurance and media scan are always activated

B. by deploying secure-capable drives

C. by turning on cyclic redundancy checks (CRCs)

D. by turning on erasure coding

 

Correct Answer: A


New Question 15:

 

Click the Exhibit button.

new ns0-515 dumps questions 15

Referring to the exhibit, what would you select in the search list to see all of the host selections for NetApp E-Series storage systems?

A. Storage OS

B. SANtricity

C. E-Series SAN Host

D. E-Series Controller Firmware

 

Correct Answer: C

Reference https://www.google.com/url?sa=tandrct=jandq=andesrc=sandsource=webandcd=1andved=2ahUKEwirltOiyqvnAhVhu3EKHcUrBjsQFjAAegQIAhABandurl=https%3A%2F%2Fcommunity.netapp.com%2Ffukiw75442%2Fattachments% 2Ffukiw75442%2Fe-series-santricity-and-related-plug-ins-discussions%2F557%2F1%2FIMT_E-Series_SAN_Host_20180424_090321201.pdfandusg=AOvVaw1LNpV6vBUxZXiyfgdcnlSz


 

NetAppexamdumps is a website for collecting Netapp certification resources. This site shares all popular exam items of Netapp Data Track, Hybrid Cloud Track, and Converged Infrastructure Track.

Part of the Netapp NS0-515 dumps exam questions and answers shared above are for candidate verification, welcome to download the latest NS0-515 dumps:https://www.leads4pass.com/ns0-515.html (59 Q&A PDF+VCE), Guaranteed first-attempt pass for the NetApp Certified Implementation Engineer – SAN, E-Series (NS0-515) exam.

BTW, download a part of Netapp NS0-515 dumps PDF to study locally: https://drive.google.com/file/d/1eCRmfp1r4NSsBLOmHLZXbZIsjkt172iK/

On the Netappexamdumps platform, you can search for all free NetApp exam questions and test or practice for yourself online. And you can download PDF files. Any other questions, you can email [email protected]