Lead4Pass NS0-175 dumps with PDF file and VCE practice exam engine contains 60 up-to-date exam questions and answers covering Cisco and NetApp FlexPod Design (NS0-175) exam topics.
Candidates only need to download NS0-175 dumps PDF or NS0-175 dumps VCE: https://www.leads4pass.com/ns0-175.html (NS0-175 dumps), and practice hard to ensure 100% pass the exam.
Cisco and NetApp FlexPod Design (NS0-175) exam include Flexpod Design, Networking, Security, and Tools.
Share part of Netapp NS0-175 dumps PDF online download for free:
https://drive.google.com/file/d/1TZR9RLi7T51JjPEdgdo_iemdKvocoJuT/
The following is a comprehensive sharing of some of the latest Netapp NS0-175 dumps exam questions and answers:
Number of exam questions | Exam name | From | Release time |
15 | Cisco and NetApp FlexPod Design Specialist | Lead4Pass | Dec 14, 2022 |
New Question 1:
You are sizing a5 FlexPod Datacenter solution for multitenancy use.
What are two important platform scaling considerations in this scenario? (Choose two.)
A. maximum NetApp ONTAP cluster limits
B. maximum NetApp ONTAP storage VM limits
C. maximum Cisco vPC interfaces between Fabric Interconnects
D. maximum Cisco L1, L2 interfaces between Fabric Interconnects
Correct Answer: AD
New Question 2:
You are developing a FlexPod solution with a MetroCluster IP as the storage solution. In this scenario, which two components are supported? (Choose two.)
A. NetApp AFF C190
B. Cisco Nexus 3524-X/XL
C. Cisco Nexus 3232C
D. NetApp AFF A400
Correct Answer: CD
Reference: https://www.netapp.com/blog/flexpod-datacenter-solutions/
New Question 3:
You are asked to evaluate SaaS-based monitoring solutions for your FlexPod environment. Other than being SaaS-delivered, selection criteria include full lifecycle management, environment automation, and the ability to monitor third-party storage that is slated for retirement.
In this scenario, which product satisfies the requirements?
A. NetApp Cloud Insights
B. NetApp OnCommand Insight
C. Cisco UCS Manager
D. Cisco Intersight
Correct Answer: A
Reference: https://cloud.netapp.com/hubfs/WP-7302-Cloud-Insights-Monitoring-Guide.pdf
New Question 4:
You are designing a multi-site FlexPod Datacenter solution for a customer using MetroCluster over IP. The design should include a single set of compliant switches for the environment. Which two features are required to satisfy this requirement? (Choose two.)
A. support for Fibre Channel ports
B. support for an MTU size of 9216
C. support for unified switch ports
D. support for QoS
Correct Answer: AD
New Question 5:
You are sizing a FlexPod Virtual Desktop solution for a customer with 500 virtual desktops in a shared Remote Desktop Services (RDS) topology. In this scenario, which Cisco best practice should you use?
A. You should avoid placing more than 20 users per physical host
B. You should avoid over-committing physical CPU resources for virtual machines
C. You should avoid changing the virtual host disk queue depth
D. You should avoid multiple vCPUs per individual virtual machine
Correct Answer: B
New Question 6:
You have a FlexPod solution that consists of a NetApp AFF A800 storage system, a Cisco MDS 9148S switch, and a Cisco UCS 6232 Fabric Interconnect. You want to upgrade NetApp ONTAP software on the AFF A800 to take advantage of a new feature.
In this scenario, which three tools would enable you to verify if the upgrade would be performed safely? (Choose three.)
A. NetApp Interoperability Matrix Tool
B. Cisco Intersight
C. Cisco Data Center Network Manager
D. Cisco UCS Hardware and Software Compatibility List
E. NetApp Active IQ Upgrade Advisor
Correct Answer: ABC
New Question 7:
You are designing a new FlexPod solution to use with VMware vSphere by using NFS datastores and want to ensure maximum availability by using a PC. In this scenario, on which Cisco component would you configure vPC interfaces?
A. Cisco UCS Fabric Interconnect
B. Cisco MDS switches
C. Cisco Nexus switches
D. UCS B-Series blade server
Correct Answer: C
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_vmware_vs_7_design.html
New Question 8:
What are the three requirements for all FlexPod Datacenter solutions? (Choose three.)
A. two NetApp storage controllers in a high-availability (HA) pair configuration
B. a separate 100 Mbps Ethernet/1 Gbps Ethernet out-of-band management network
C. a pair of Fabric Extenders in a redundant configuration
D. two Cisco UCS 6200, 6300, or 6400 Series Fabric Interconnects in a redundant configuration
E. redundant boot-from-SAN LUN paths
Correct Answer: CDE
New Question 9:
A customer wants to deploy a FlexPod Datacenter solution in a limited amount of rack space. After planning for the networking and storage devices required for the deployment, they realize they have six rack units of space remaining. They need to install as many servers as possible in this available rack space.
In this scenario, which solution allows them to accomplish their objective?
A. three Cisco UCS C4200 rack servers
B. four Cisco UCS B480 M blade servers
C. six Cisco UCS C220 M5 rack servers
D. eight Cisco UCS B200 M5 blade servers
Correct Answer: D
New Question 10:
A customer is verifying that they have separation on their FC switch fabric to protect their FlexPod solution from their other storage devices. Which two technologies enable the customer to accomplish this task? (Choose two.)
A. WWPN zoning
B. VASN
C. IQN igroup
D. VLAN
Correct Answer: AD
New Question 11:
A customer is deploying a FlexPod Datacenter and planning to boot from SAN each of their UCS blades using the Fibre Channel Protocol. In this scenario, which three actions would accomplish their objective? (Choose three.)
A. Use only a pair of Cisco Nexus 9318YC-FX switches
B. Create an igroup on the NetApp ONTAP storage system with the appropriate IQNs
C. Use only a pair of Cisco Nexus 9336C-FX2 switches
D. Use a pair of Cisco MDS 9148T and a fair of Cisco 9336C-FX2 switches together
E. Create an igroup on the NetApp ONTAP storage system with the appropriate WWPNs
Correct Answer: ABE
New Question 12:
A customer is unhappy with their current data center infrastructure. They want to purchase a FlexPod system to replace it. The customer asks you to help them understand the benefits of Solution Support to determine which support model would suit them best.
In this scenario, which three statements are correct? (Choose three.)
A. You have a single point of contact for all cases
B. Solution Support is a lower-cost support option
C. There is no need to diagnose the problem before you call support
D. Customers do not need to open tickets; all issues are automatically reported
E. Issues are solved by solution experts
Correct Answer: ABE
New Question 13:
Your environment currently has a 12-node NetApp cluster serving iSCSI. You need to add at least four more nodes to serve FC in your environment. In this scenario, what should you do?
A. You can safely add up to 4 more storage controllers in the current cluster
B. You can safely add up to 6 more storage controllers in the current cluster
C. You must create a new cluster with the new storage controllers
D. You can safely add up to 12 more storage controllers in the current cluster
Correct Answer: A
New Question 14:
A customer wants to upgrade their code fabric between each site with a modular chassis switch that supports up to 400GbE per port to accommodate more business transaction volume. In this scenario, which device would help them accomplish their objective?
A. Cisco Nexus 9504
B. Cisco Nexus 9332C
C. Cisco MDS 9706
D. Cisco Catalyst 9400
Correct Answer: A
New Question 15:
You have a customer that wants to deploy a new data center environment and take advantage of server portability. You propose that they use Cisco UCS servers to take advantage of stateless computing operations. In this scenario, which Cisco UCS feature would help the customer achieve their objective?
A. SEL logs
B. MAC address pools
C. Service Profiles
D. VSANs
Correct Answer: C
Reference: https://community.cisco.com/t5/data-center-documents/what-is-stateless-computing-in-ucs/ta-p/3116244
…
NetAppexamdumps is a website for collecting Netapp certification resources. This site shares all popular exam items of Netapp Data Track, Hybrid Cloud Track, and Converged Infrastructure Track.
Part of the Netapp NS0-175 dumps exam questions and answers shared above are for candidate verification, welcome to download the latest NS0-175 dumps: https://www.leads4pass.com/ns0-175.html (60 Q&A PDF+VCE), Guaranteed first-attempt pass for the Cisco and NetApp FlexPod Design (NS0-175) exam.
BTW, download a part of Netapp NS0-175 dumps PDF to study locally:
https://drive.google.com/file/d/1TZR9RLi7T51JjPEdgdo_iemdKvocoJuT/